Automatically initiates a 1.1 gpf or 1.6 gpf flush based on how long the user remains in sensor range
Buttons on top of the flush valve enable manual flushing with a full or reduced flush at restroom visitor’s discretion
Employs an infrared sensor with multiple-focused, lobular sensing fields for high and low target detection
User-friendly, three-second flush delay
High copper, low zinc brass castings for dezincification resistance
Fixed metering bypass and no external volume adjustment to ensure water conservation
Valve body, Cover, Tailpiece and Control Stop shall be in compliance with ASTM Alloy Classification for Semi-Red Brass
Valve shall be in compliance to the applicable sections of ASSE 1037
Designed to maximize and complement Sloan flushometers
Universal model works with Sloan flushometers from 1.1 to 1.6 gpf
Durable, hygienic vitreous china construction with elongated rim
Syphonjet flushing achieves 1000g Map Scores when used with Sloan flushometers
IAPMO certified to meet or exceed ASME A112.19.2 standards
Meets ADA guidelines and ANSI A117.1 requirements when installed accordingly