Designed for under-the-lavatory applications where the outlet temperature of hot water must be controlled for safe, economic use
Installs in place of the Tee fitting supplied with the faucet prior to the solenoid valve
Designed to quickly sense and compensate for temperature fluctuations induced by water temperature and pressure changes in the supply line
Rugged construction features solid brass valve body and corrosion resistant internal components
Water temperature adjustment stem with lock nut to prevent tampering
Equipped with integral check valves at inlets
3/8” compression connection on inlets and outlet
Meets all the performance standards of ASSE 1070 and CSA B125
Capacity — standard: 4.0 gpm (15.0 Lpm)
At 45 PSI differential (310 kPa), with hot water supply between 140°-180° F (60°-82° C).
Maximum Hot Water Supply Temperature: 180° F (82° C)
Minimum Hot Water Supply Temperature: 5° F (2.8° C) above set point
Maximum Operating Pressure: 125 psig (862kPa)
Minimum flow — standard: 0.25 gpm (1.0 Lpm) to ASSE 1016
Factory set: 105° F (40° C)